설명
SLP845 Hermetic Single Point Load Cell
The SLP845 is the ideal solution for scales, packaging and process weighing where a hermetically sealed stainless steel load cell is required for harsh chemical and washdown environments. Due to the low profile the integration into any system is easy. The broad capacity range and large platform size allows wide application in industrial weighing applications.

Wash Down Applications
SLP845 is the right choice for the food or pharmaceutical industry where daily wash down is required. It provides best weighing performance in a hermetically sealed stainless steel load cell. Thus it is ideal for stainless steel scales or general weighing applications where the highest grade of IP protection and corrosion resistance is required.
Off-Center Compensation
One load cell can be used to support a weighing platform and, due to the off-center load compensation, the SSH will weigh within tolerance regardless of load application point.
Robustness
SLP845 is an extremely robust single point load cell suitable for almost all industrial environments. It allows 50% static overload without compromising the weighing performance.
| Parameter | unit ofmeasure | Specification | |||||
|---|---|---|---|---|---|---|---|
| Model No. | SLP 845 | ||||||
| Rated Capacity (R.C.) | kg(lb) | 15 (33) | 22 (48) | 50 (110) | 100 (220) | 200 (441) | |
| Rated Output | mV/V @R.C. | 2 ± 10% | |||||
| Zero load Output | %R.C. | ≤ 1.0 | |||||
| Combined Error 1) 2) | %R.C. | ≤ 0.018 | |||||
| Repeatability Error | %A.L.3) | ≤ 0.01 | |||||
| Creep, 30 minute | %A.L. | ≤ 0.017 | |||||
| Min. Dead Load OutputReturn (DR), 30 min | %A.L. | ≤ 0.017 | |||||
| Temperature Effect on | Min. Dead load Output | %R.C./°C | ≤ 0.001(0.0007) ; 0.003 (0.0016) | ||||
| Sensitivity 2) | %A.L./°C | ≤ 0.001 (0.0006) | |||||
| Temperature Range | Compensated | °C (°F) | -10 ~ +40 (+14 ~+104) | ||||
| Operating | -40 ~ +65(-40 ~ +150) | ||||||
| Safe Storage | -40 ~ +80(-40 ~ +176) | ||||||
| OIML / European Approval 4) | OIML Cert. No. | R60/2000-NL1-12.55 / TC8077 | |||||
| European Cert. No. | C | ||||||
| Class | 3000 | ||||||
| nmax | 3000 | ||||||
| vmin | g | 1 ; 2 | 2 ; 5 | 5 ; 10 | 10 ; 20 | 20 ; 50 | |
| PLC | 0.7 | ||||||
| Humidity Symbol | CH | ||||||
| Min. dead load | kg | 0.1 | |||||
| Z | 3000 | ||||||
| Barometric Pressure Effects | None | ||||||
| NTEP Approval 4) | Number | 13-002 | |||||
| Class | III S | ||||||
| nmax | 5000 | ||||||
| Vmin | lb | 0.002 ; 0.005 | 0.005 ; 0.01 | 0.01 ; 0.02 | 0.02 ; 0.05 | 0.05 ; 0.1 | |
| Min. dead load | lb | 0.05 | 0.15 | ||||
| ATEX Approval 4) | Number | DEKRA 13ATEX0045 / DEKRA 13ATEX0046 | |||||
| Rating | II 2G Ex ib IIC T4 Gb / II 2D Ex ib IIIC T100℃ Db | ||||||
| II 3G Ex ic IIC T4 Gc / II 3G Ex nA IIC T4 Gc / II 3D Ex tc IIIC T100℃ Dc | |||||||
| Entity Parameters | Ui/Un = 20V, Ii = 600mA, Pi = 1.25W, Ci = 6nF, Li = 30µH | ||||||
| Factory Mutual Approval 4) | Number, USA | FM18US0025 | |||||
| Rating USA | IS / I, II, III/ 1 / ABCDEFG / T4 Entity | ||||||
| NI / I / 2 / ABCD/ T6 NIFW; S / II, III / 2 / FG / T6 | |||||||
| Entity Parameters | Vmax=20V, Imax=600mA, Pi=1.25W, Ci=0,Li=0; NIFW: Vmax=20V,Imax=600mA, Ci= 0,Li=0 | ||||||
| System Drawing No, USA | 30036645 | ||||||
| Excitation Voltage | Recommended | V AC/DC | 5~15 | ||||
| Max. | 20 | ||||||
| Terminal Resistance | Excitation | Ω | 1116 ± 20 | ||||
| Output | 1000 ± 3 | ||||||
| Insulation Resistance @50VDC | MΩ | 1116 ± 20 | |||||
| Breakdown Voltage | V AC | 1000 ± 3 | |||||
| Material | Spring Element | 17-4PH stainless steel | |||||
| Enclosure | 304 stainless steel | ||||||
| Cable entry fitting | 304 stainless steel | ||||||
| Cable | PVC | ||||||
| Protection | Type | sealed | |||||
| IP Rating | IP68, IP69K | ||||||
| NEMA Rating | NEMA 6/6P | ||||||
| Overload Protection | NO | ||||||
| Load Limit | Safe | %R.C. | 150 | ||||
| Ultimate | 300 | ||||||
| Safe Side Load | %R.C. | 100 | |||||
| Safe Dynamic Load | %R.C. | 70 | |||||
| Fatigue Life | cycles @R.C. | 1,000,000 | |||||
| Direction of Loading | Beam | ||||||
| Deflection @ R.C., nominal | mm (in) | 0.18 (0.007) | 0.15 (0.006) | 0.18 (0.007) | 0.18 (0.007) | 0.22 (0.009) | |
| Weight, nominal | kg (lb) | 1.3(3) | |||||
| Cable | Length | m (ft) | 3 (9.8) | ||||
| Diameter | mm (in) | 6.2 (0.24) | |||||
| Mounting Screw | Grade | A4-70 | |||||
| Size / thread | mm | M6x1 | |||||
| Engaged Length | mm | 10 (0.4) | |||||
| Torque, nominal | Nm | 10 (7.4) | |||||
| Max Platter Size | cm x cm (in x in) | 30 x 30 (11.8 x 11.8) | 40 x 50 (15.7 x 19.7) | ||||
| Off Center Load Error @33%R.C. | %A.L./cm (../in) | 0.0044 (0.011) | |||||
1) Error due to the combined effect of non-linearity and hysteresis
2) Typical values only. The sum of errors due to Combined Error and Temperature Effect on Sensitivity comply with the requirements of OIML R60 and NIST HB44.
3) A.L. = Applied Load
4) See certificate for complete information.
SLP845 15–200 kg Load Cell Dimensional Drawings mm [inch]

SLP845 Load Cell Order Information
| Description | Item No. |
|---|---|
| Load Cell SLP845-15KG 3M C3/III S n:5 vmin 1g/0.002lb | 72244433 |
| Load Cell SLP845-15KG 3M C3/III S n:5 vmin 2g/0.005lb | 72244437 |
| Load Cell SLP845-22KG 3M C3/III S n:5 vmin 2g/0.005lb | 72244429 |
| Load Cell SLP845-22KG 3M C3/III S n:5 vmin 5g/0.01lb | 72244431 |
| Load Cell SLP845-50KG 3M C3/III S n:5 vmin 5g/0.01lb | 72244426 |
| Load Cell SLP845-50KG 3M C3/III S n:5 vmin 10g/0.02lb | 72244428 |
| Load Cell SLP845-100KG 3M C3/III S n:5 vmin 10g/0.02lb | 72244423 |
| Load Cell SLP845-100KG 3M C3/III S n:5 vmin 20g/0.05lb | 72244425 |
| Load Cell SLP845-200KG 3M C3/III S n:5 vmin 20g/0.05lb | 72244420 |
| Load Cell SLP845-200KG 3M C3/III S n:5 vmin 50g/0.1lb | 72244422 |
| Bolded entries are stocked |
SLP845 Load Cell Cable Colours
| Colour | Function |
|---|---|
| Green | + Excitation |
| Black | – Excitation |
| Red | + Signal |
| White | – Signal |
| Blue | + Sense |
| Brown | – Sense |
| Yellow (Long) | + Shield |