scaime / Bending Beam Load Cell F60X-6W with a Rated Load of 10 … 500 kg

  • Load cell made of stainless steel, hermetically sealed to IP68, IP69K
  • Approved up to 6 000 d OIML for use in legal for trade weighing applications
  • Load cell Ideally suited for high accuracy industrial weighing applications such as dosing machines and tank, vessel or hopper weighing
  • Optimized load cell version for easy corner adjustment
  • Capacities : 5, 10, 20, 50, 100, 200, 300, 500 kg
브랜드:

설명

Bending Beam Load Cell F60X-6W with a Rated Load of 10 … 500 kg

PRODUCT FEATURES

  • Bending beam load cell made of stainless steel, hermetically welded with protection class IP68
  • OIML R60 approved up to 6000d and NTEP approved 5000d
  • 6-wire technology
  • Ideally suited for industrial weighing applications requiring high accuracy
  • Signal output with increased accuracy of ±0.05% of rated output (optional)
  • ATEX 2014/34/EU version available for hazardous areas (optional)

APPLICATIONS

  • Hoppers, tanks, mixers, or conveyors
  • Beverages and food industry
  • Mining, metals, and minerals
  • Chemical and pharmaceutical industry
  • Waste management / recycling
  • Packaging technology

Dimensions in mm

Warning : The F60X load cell installation requires mounting hardware with a minimum hardness of 53 HRC and screws of class 12.9

Article-No. Version Rated Load [kg] nmax [d OIML] Weight [kg]
117828 C3 10e 10  

 

 

 

 

3000

 

 

 

 

 

 

 

 

 

 

 

0.45

117829 C3 10e 20
117830 C3 10e 50
117831 C3 10e 100
117624 C3 10e 200
117832 C3 10e 300
117623 C3 10e 500
117833 C6 10e 10  

 

 

 

 

6000

117834 C6 10e 20
117835 C6 10e 50
117836 C6 10e 100
117837 C6 10e 200
117838 C6 10e 300
117839 C6 10e 500

Connection Assignment

Electrical Connection
Function Wire Color
Excitation (+) Blue
Signal (+) White
Signal (-) Red
Excitation (-) Black
Sensing (+) Green
Sensing (-) Gray

Technical Data

Type   F60X-6W  
Version   C3 10e C6 10e
Rated load E kg 10; 20; 50; 100; 200; 300; 500
Maximum load for approved weighing Emax kg 10; 20; 50; 100; 200; 300; 500
Accuracy class OIML R60   C3 C6
Maximum numbers of load cell intervals nmax d OIML 3000 6000
Minimum verification interval vmin kg E/10000 E/10000
Creep division factor Z = Emax / 2 x DR 3000 6000
Combined error % E ±0.017 ±0.008
Temperature coefficient of zero signal % E/ °C ±0.0014 ±0.0014
Temperature coefficient of characteristic value % E / °C ±0.0014 ±0.0007
Load creep dcr, F in 30 min. % E ±0.025 ±0.012
Zero balance % E ±2.5
Rated output at E Cnom mV/V 2 ±1 % (option ±0.05 %)
Rated range of excitation voltage BU, nom V 1 … 15
Input resistance Re Ω 385 ±20
Output resistance Ra Ω 350 ±5
Insulation resistance Ris MΩ/50V 5000
Electrical connection   Cable, PVC, 3 m
Rated temperature range BT, nom °C -10 … 40
Operating temperature range BT, G °C -20 … 60
Limit load Elim % Emax 150
Breaking load Eb % Emax 200
Tightening torque Nm 25
Level of protection EN 60529 IP68
Material   Stainless steel
Weight kg 0.45

Options

Article-No. Description
107798 ATEX 2014/34/EU, IECEx:

ex II 1 G/D, Ex ia IIC T6 Ga, Ex ia IIIC T80 °C Da, IP6X, -20 °C < Ta < +60 °C (zones gaz 0/1/2, dust 20/21/22)

115049 ATEX 2014/34/EU, IECEx:

ex II 1 D, Ex ta IIIC T125 °C Da, IP6X, -20 °C < Ta < +60 °C (zones dust 20/21/22)

115048 ATEX 2014/34/EU, IECEx: ex II 3 G, Ex nA IIC T6 Gc, -20 °C < Ta < +60 °C (zone gaz 2)
 

Marking FACTORY MUTUAL (FM): I.S., CL I, II, III / DIV 1 / GP ABCDEFG

N.I., CL I, II, III / DIV 2 / GP ABCDEFG; NIFW

 

 