Schenck Process / RTB / Ring Torsion Load Cell

• Legal-for-trade design according to OIML
• High accuracy, even for very small application areas (for legal-for-trade applications up to at least 15 %)
• Low power consumption due to high input impedance of 1100 Ω
• ATEX/IECEx approval for category 1GD (intrinsically safe to operate) or 3GD (not intrinsically safe)
• Protection class IP68

설명

RTB Ring Torsion Load Cell

More Information
RTB 0,25 t C3 RTB 0,5 t C3 RTB 0,25t C3 MR RTB 0,50 t MR
SKU VP4225901 VP4226101 VP4226001 VP4226201
Order number V041086.B01 V041087.B01 V041086.B07 V041087.B07
Weight [kg] 1 1.05 0.83 1
HS-Code 8423 90 10 8423 90 10 8423 90 10 9031 80 20
Estimated Delivery Time [Weeks] 28 28 28 28
Accuracy C3 C3 C3 C3
Capacity [t] 0.25 0.5 0.25 0.25
ATEX-Category None None None None
Product Family SENSiQ Loadcell RTB SENSiQ Loadcell RTB SENSiQ Loadcell RTB SENSiQ Loadcell RTB
Application
The load cell as transducer converts the mechanical input variable force proportionally into the electronic output variable voltage.
The specific model of the ring torsion load cell offers the user specific advantages:
• The extremely small frame size simplifies the use in almost all weighing device applications.
• The robust construction allows problem-free transport, installation and operation, also under rough ambient conditions (disturbance forces, temperature).
Design
• Hermetically sealed encapsulation through laser welding and  glass-metal implementation (IP68)
• Corrosion protection through the use of stainless steel
• All electrical components are located inside the load cell and thus are optimally protected.
• The high quality and robust connecting cable is guided radially into the load cell.
• Mechanically compatible with the RTK type series
Function
• High reproducibility
• High long-term stability and therefore consistently high accuracy permanently
• Extremely small measured value influence as a result of lateral forces
• High functional safety, even with frequently unavoidable impact loads and constraining forces, as well as with electrical interferences
• Torque-free force input/output as a result of the direct, vertical power train
Dimension
RTB 0.13 t RTB 0.25 t / 0.5 t

Technical Data

Nominal load Emax 0.13 t 0.25 t 0.5 t 0.5 t
Accuracy class C3 C3 C3 C5 Ref
Nominal characteristic value Cn 1 mV/V
±0.1 mV/V
1.75 mV/V
2 mV/V
±0.2 mV/V
±0.1 mV/V
2 mV/V
±0.1 mV/V
Compound error Fcomb ±0.023 % ±0.023 % ±0.014 % Cn
Return to zero signal after load (30 min) Fdr ±0.0167 % ±0.0167 % ±0.0083 % Cn
Creepage under load (30 min) Fcr ±0.012 % ±0.0245 % ±0.0123 % Cn, Btn
Hysteresis ±0.017 % ±0.0167 % ±0.0083 % Cn, Btn
Temperature coefficient of the zero signal per 10 K TK0 ±0.008 %
±0.014 %
±0.007 %
±0.009 %
±0.009 %
Cn, Btn
Option MR
Temperature coefficient of the characteristic value per 10 K TKc ±0.008 % ±0.01 % ±0.005 % Cn, Btn
Max. allowed number of verifi- able division values nLC 3000 3000 5000
Smallest scale interval Vmin Emax/17500
Emax/10000
Emax/20000
Emax/17500
Emax/17500
Standard
Option MR
Minimum application range Bamin 17 %
30 %
15 %
40 % Emax
Option MR
Max. application range Bamax  100 % Emax
Maximum capacity * Ll  150 % Emax
Max. lateral load ** Lq  20 % Emax
Input resistance Re 1260 Ω ±100 Ω 1100 Ω ±100 Ω 1100 Ω ±100 Ω 1100 Ω ±100 Ω
Output resistance Ra 1020 Ω ±0.5 Ω 1025 Ω ±25 Ω 1025 Ω ±25 Ω 1025 Ω ±25 Ω
Zero Signal S0 1 % 1.5 % 1 % 1 % Cn
Supply voltage Us  max. 30 V (recommended: 5 V – 15 V)
Nominal temperature Btn  -10 °C … +40 °C
Operating temperature range Btu -30 °C … +70 °C -35 °C … +70 °C -35 °C … +70 °C -35 °C … +70 °C
Storage temperature range  -50 °C … +90 °C
Type of protection IP68
Cable specification – Cable length 5 m, shield insulated from housing (0.13 t) or connected to –housing (0.25 0.50 t)
Connection assignment  Input +82: pink / Input -81: gray
Output +28: brown / Output -27: white
Material  Stainless steel
Corrosion protection  see resistance table DDP8 483
Recommended tightening torque for the fastening bolts 8 N m 12 … 14 N m 12 … 14 N m 12 … 14 N m

* Permissible vibration stress according to DIN 50100: 70 % Emax; peak loading values may not exceed Emax.
** In combination with elastomer bearings, SEM must be observed that the reset force of the elastomer bearings already represents a transverse force.

ATEX approval

Only operate intrinsically safely II 1G Ex ia IIC T4 Ga
II 1D Ex ia IIIC T73°C Da
Not operated intrinsically safely II 3G Ex nA IIC T4 Gc
II 3D Ex tc IIIC T63°C Dc

Order numbers

Version [t] Accuracy class C3 Accuracy class C5
0.13 V041085.B01
0.25 V041086.B01
0.50 V041087.B01 V041087.B05
0.25 MR V041086.B07
0.50 MR V041087.B07
Order numbers ATEX/IECEX version

II 1G Ex ia IIC T4 Ga / II 1D Ex ia IIIC T73°C Da / II 3G Ex nA IIC T4 Gc / II 3D Ex tc IIIC T63°C Dc *

0.13 V041085.B11
0.25 V041086.B11
0.50 V041087.B11 V041087.B15

* Tick the appropriate box on the type plate to indicate whether the load cell is used in the 1GD or 3GD area. For category 1GD or 2GD, the load cell must be connected intrinsically safe.

Installation accessories

  • SENSiQ Secure Mount SSM
  • SENSiQ Elastomer Mount SEM

 

상품평

아직 상품평이 없습니다.

“Schenck Process / RTB / Ring Torsion Load Cell”의 첫 상품평을 남겨주세요