설명
SINGLE-POINT LOAD CELL, PWS TYPE 10…700 kg
| Nominal sensitivity | 2 ±0,002 mVN |
| Combined error | 0,05 % (*) |
| Sensitivity temperature coefficient, Tkc | 0,045 %/10K (*) |
| Zero signal temperature coefficient, Tko | 0,045 %/10K (*) |
| Zero signal tolerance | :5 2,0 % (*) |
| Compensated temp. range | -10 to +40 oc |
| Service temperature range | -30 to +70 oc |
| Storage temperature range | -50 to +85 oc |
| Max. excitation voltage. | 15 V |
| Input resistance | min 350 Q |
| Output resistance | 350 ±3 Q |
| Isolation resistance | > 5000 MO |
| Limit load rel. to rated load | 150 % |
| Breaking load / rated load | 300 % |
| Corner load error at 50% rated load | 0,05 %/100mm |
| Corner load error at 50% rated load (#) | 0,5 %/100mm |
| Material | stainless steel |
| Protection class | IP65 |
| (*) Error related to rated load | |
| (#) at rated load 500 and 700 kg |
Electrical Cable: 6 Conductor+ Shield, 5m long
Cable Colour Code:
| Function | Color |
|---|---|
| Input Voltage + | Green |
| Input Voltage – | Black |
| Measuring Signal + | White |
| Measuring Signal – | Red |
| Sensor Conductor + | Orange |
| Sensor Conductor – | Blue |
| Shield | Yellow (isolated over entire length) |
The connecting cable shield is not connected to the measuring body. Therefore, load cell grounding has to be provided for, e.g. via the connecting structure.
Dimensions

Arrow-head on front side = Measuring force direction
| Emax= Rated load | Part= Material No.: | “A” I | “B” I | “C” | Torque | Full range to travel | ATEX
Category |
| (mm | |||||||
| 10 kg | V058895.B01 | 8,5 | M8 | 23,8 | 32 Nm | 0,30 mm | – |
| 30 kg | V058895.B02 | 8,5 | M8 | 30,7 | 32 Nm | 0,35 mm | – |
| 60 kg | V058895.B03 | 8,5 | M8 | 30,7 | 32 Nm | 0,35 mm | – |
| 100 kg | V058895.B04 | 8,5 | M8 | 30,7 | 32 Nm | 0,45 mm | – |
| 150 kg | V058895.B05 | 8,5 | M8 | 30,7 | 39 Nm | 0,45 mm | – |
| 300 kg | V058895.B06 | 8,5 | M8 | 30,7 | 39 Nm | 0,50 mm | – |
| 500 kg | V058895.B07 | 10,4 | M10 | 36,5 | 79 Nm | 0,50 mm | – |
| 700 kg | V058895.B08 | 10,4 | M10 | 36,5 | 79 NM | 0,50 mm | – |
| 10 kg | V058895.B11 | 8,5 | M8 | 23,8 | 32 Nm | 0,30 mm | 2G/D |
| 30 kg | V058895.B12 | 8,5 | M8 | 30,7 | 32 Nm | 0,35 mm | 2G/D |
| 60 kg | V058895. B13 | 8,5 | M8 | 30,7 | 32 Nm | 0,35 mm | 2G/D |
| 100 kg | V058895.B14 | 8,5 | M8 | 30,7 | 32 Nm | 0,45 mm | 2G/D |
| 150 kg | V058895. B15 | 8,5 | M8 | 30,7 | 39 Nm | 0,45 mm | 2G/D |
| 300 kg | V058895.B16 | 8,5 | M8 | 30,7 | 39 Nm | 0,50 mm | 2G/D |
| 10 kg | V058895.B21 | 8,5 | M8 | 23,8 | 32 Nm | 0,30 mm | 3G/D |
| 30 kg | V058895.B22 | 8,5 | M8 | 30,7 | 32 Nm | 0,35 mm | 3G/D |
| 60 kg | V058895.B23 | 8,5 | M8 | 30,7 | 32 Nm | 0,35 mm | 3G/D |
| 100 kg | V058895.B24 | 8,5 | M8 | 30,7 | 32 Nm | 0,45 mm | 3G/D |
| 150 kg | V058895.B25 | 8,5 | M8 | 30,7 | 39 Nm | 0,45 mm | 3G/D |
| 300 kg | V058895.B26 | 8,5 | M8 | 30,7 | 39 Nm | 0,50 mm | 3G/D |
| Parameter | Value | Unit | Description |
|---|---|---|---|
| Combined Error | 0.02 | % | Combined measurement error |
| Tko | 0.014 | % | Temperature effect on zero |
| Tkc | 0.018 | % | Temperature effect on sensitivity |
| Accuracy Class | C3 | – | According to OIML R60 |
| Max. number of increments (n) | 3000 | d | Maximum verification scale intervals |
| Minimum utilization (Bamin) | 42 | % | At 3000d |
Minimum Load Cell Resolution
The minimum load cell resolution is calculated as follows:
Vmin = Emax / wz
where wz = 7143
Example (PWS 100 kg model)
Item Value
Rated capacity (Emax) 100 kg
Minimum utilization (Bamin) 42 kg (42% of 100 kg)
Theoretical minimum resolution 100,000 g ÷ 7143 ≈ 14 g
Practical scale interval 20 g
In theory, the minimum resolution is 14 g. However, in practice, the weighing indicator uses the next available scale interval, which is 20 g.