설명
Model F1106 Hydraulic compression force transducer
Compact version to 60 kN
The compact hydraulic compression force transducer is available from a rated load of 160 N to 60 kN. Hydraulic force measurement is a simple way to capture and display the forces occurring in various applications. Applications for hydraulic force measurement can be found in equipment manufacturing, in device and special machine building and also with measuring and control systems.
The force is measured using the principle of hydraulics: The force acting on a piston leads to a pressure increase that can be visualised on a connected display instrument. The scale of the display instrument can be defined in various units e.g. N, kN, kg, t.
Leak-tightness warranty
The warranty on leak tightness of the hydraulic force measu-ring unit was extended to 5 years. The prerequisite for this is of course the intended use of the force measuring unit. A force transducer that starts to leak within this period will be repaired free of charge. In this way, we are underlining the quality of our hydraulic force transducers and our confidence in our own technology.
Specifications per VDI/VDE/DKD 2638
| Parameter | Value |
|---|---|
| Rated force (Fnom) | 0 … 160 N up to 0 … 60 kN |
| [0 … 36 lbf up to 0 … 13,489 lbf] | |
| Nominal size (NS) | 10 |
| Display – Standard | Pressure gauge 213.40 (NS 63) |
| Display – Option | Pressure gauge with contacts PSG23 |
| Digital pressure gauge DG-10 | |
| Optional (on request) | Pressure sensor |
| Relative linearity error (dlin) – Standard | ≤ ±1.6 % Fnom (analogue display) |
| Relative linearity error (dlin) – Option | ≤ ±0.5 % Fnom (pressure sensor / digital pressure gauge) |
| Limit force (FL) | 100 % Fnom |
| Breaking force (FB) | > 130 % Fnom |
| Rated displacement (snom) | < 0.5 mm [< 0.02 in] |
| Rated temperature range (BT, nom) | -25 … +50 °C [-13 … 122 °F] |
| Ingress protection (EN/IEC 60529) | IP65 |
| Case material | Stainless steel |
| Piston material | Stainless steel |
| Mounting type – Standard | Adapter L = 50 mm [1.96 in] |
| Mounting type – Option | Direct mounting |
| Capillary | |
| Measuring hose (“separation without any losses”) | |
| Fill fluid | Glycerine 70 % / Water 30 % |
| Assembly aid | Threaded holes on bottom of case |
| Options | Mounting flange / Spacer disc |
| Weight | 1.2 kg [2.65 lbs] (with pressure gauge 213.40) |
| 1.4 kg [3.1 lbs] (with digital pressure gauge DG-10) |
Dimensions in mm [in]

= possible selection
1) For a rated force below 500 N, the relative linearity error is ≤ ±1.6 % Fnom for all connected measuring instruments.
2) Relative linearity error ≤ ±1.0 % Fnom


상품평