Tedea Huntleigh / Model 1510 Hermetically Sealed Single-Point Load Cell

The load cell model 1510 is a high accuracy stainless steel single-point load cell suitable to industrial application which undergo regular washdown, typically platforms, wall scales and other process weighing applications in the food industry. Hermetically sealed to IP68 against moisture, the all welded construction of the 1510 enables continuous operation in harsh environments while maintaining a high operating specification. The load cell is OIML R60 and NTEP approved. For hazardous environments this load cell has EEx ia IIC T6 level approved version available.

Category:
브랜드: ,

설명

Model 1510 Hermetically Sealed Single-Point Load Cell

FEATURES
• Capacity range: 100–500 kg
• Stainless steel construction
• Single-point 600 x 600 mm platform
• OIML R60 and NTEP approved
• IP68 protection
• Optional
❍ EEx ia IIC T6 hazardous area approval
❍ FM approval available
❍ Platform size 600 x 800 mm available

APPLICATIONS
• Food industry platforms
• Marine and hybrid scales
• Process weighing hoppers
• Harsh environment

SPECIFICATIONS
PARAMETER VALUE UNIT
Rated capacity—R.C. (Emax) 100, 250, 500 kg
NTEP/OIML accuracy class NTEP Non-approved C3* C4*  
Maximum no. of intervals (n) 5000 single 1000 3000 4000  
Y = Emax/Vmin 11425 1400 10000 12000 Maximum available 12500
Rated output—R.O. 2.0 mV/V
Rated output tolerance 0.2 ±mV/V
Zero balance 0.2 ±mV/V
Zero return, 30 min. 0.0170 0.0060 0.0170 0.0130 ±% of applied load
Total Error 0.0200 0.0300 0.0200 0.0150 ±% of rated output
Temperature effect on zero 0.0023 0.010 0.0014 0.0011 ±% of rated output/°C
Temperature effect on output 0.001 0.0040 0.0010 0.0008 ±% of applied load/°C
Eccentric loading error 0.0016 0.0035 0.0011 0.0008 ±% of rated load/cm
Temperature range, compensated –10 to +40 °C
Temperature range, safe –20 to +70 °C
Maximum safe central overload 150 % of R.C.
Ultimate central overload 300 % of R.C.
Excitation, recommended 10 VDC or VAC RMS
Excitation, maximum 15 VDC or VAC RMS
Input impedance 380±10 Ω
Output impedance 350±2 Ω
Insulation resistance >1000
Cable length 3 m
Cable type 6-wire, braided, polyurethane, dual loating screen Standard
Construction Stainless steel  
Environmental protection IP68  
Recommended torque 22.0 N*m

All speciications subject to change without notice.