AEP transducers / FT6 / OFF CENTER Load Cell

Load cell suitable to work in hostile environments.
Platform size: 400 X 400 mm
High mechanical resistance
Completely made of STAINLESS STEEL
High mechanical resistance
Completely LASER welded
Degree of protection IP67
Long term stability

브랜드:

설명

OFF CENTER load cell for the measurement of static and dynamic loads

Nominal Load from 5 kg to 100 kg
Class (OIML R60) C2
Combined Error: 0,028%
Output: 2mV/V

LOAD 5 kg 10 kg 20 kg 30 kg 50 kg 100 kg CODE
CFT65KC25 CFT610KC25 CFT620KC25 CFT630KC25 CFT650KC25 CFT6100KC25

Dimensions [mm]

Platform size: 400 X 400 mm

Technical Data

ACCURACY CLASS: OIML 60 C2
LEGAL DIVISIONS 2000
NOMINAL LOAD (Emax) 5-10-20-30-50-100 kg
MIN. VERIFICATION INTERVAL (Vmin) Emax / 10000
COMBINED ERROR
NON-REPEATABILITY

ZERO RETURN over 30 min.
CREEP to nominal load:

a) over 30 min.
b) over 20 and 30 min.
≤ ±0.028%
≤ ±0.018%
≤ ±0.030%≤ ±0.029%
≤ ±0.009%
TEMPERATURE EFFECT (10 °C)
a) on zero
b) on sensitivity
≤ ±0.025%
≤ ±0.010%
NOMINAL SENSITIVITY
SENSIVITY TOLERANCE
2mV/V
≤ ±0.1%
INPUT RESISTANCE
OUTPUT RESISTANCE
INSULATION RESISTANCE
ZERO BALANCE

RECOMMENDED SUPPLY VOLTAGE
NOMINAL SUPPLY VOLTAGE
MAXIMUM SUPPLY VOLTAGE
420 ± 20W
350 ± 2W
>5 GW
≤ ±1%
10 V
1-15 V
18 V
MECHANICAL LIMIT values referred to nominal load:
a) minimum load
b) service load
c) max permissible load
d) breaking load
e) max transverse load
f) max permissible dynamic load
DISPLACEMENT AT NOMINAL LOAD
0%
120%
150%
>300%
200%
75%
~ 0.4 mm
REFERENCE TEMPERATURE
TEMPERATURE NOMINAL RANGE
SERVICE TEMPERATURE

STORAGE TEMPERATURE
+23°C
-10/+40 °C
-20/+70 °C
-20/+80 °C
WEIGHT
PROTECTION CLASS (EN 60529)
EXECUTION MATERIAL

CABLE LENGTH
~ 1.0 kg
IP67
Acciaio Inox / Stainless Steel
5m
FIXING SCREWS
a) diameter
b) resistance class
c) tightening torque
M6
12.9
10 Nm

Acceleration of gravity g=9.80434 m/s2

Electrical Connections

PVC 105°C shielded cable, Ø 5.2mm with 4 tinned Ø0.35mm2 conductors.

Shield connected to the body of the load cell.

 

 

상품평

아직 상품평이 없습니다.

“AEP transducers / FT6 / OFF CENTER Load Cell”의 첫 상품평을 남겨주세요