WIKA / Single point load cell, Model F4883

Applications
  • Checkweighers
  • Belt weighers, floor and bench scales
  • Filling applications
  • Dosing systems
Special features
  • Measuring ranges 0 … 8 kg to 0 … 300 kg [0 … 18 lbs to 0 … 661 lbs]
  • Load cell made from aluminium
  • High accuracy, react quickly, low settling time
  • Insensitive to lateral and corner load
  • Simple design, easy installation
Category:
브랜드:

설명

Single point load cell, Model F4883

The model F4883 single point load cells are a range of aluminium single point load cells suitable for a wide range of applications. Thanks to their standardised geometry and simple design, they can be easily installed in all types of scales.

The model F4883 load cells are adapted to the special requirements of checkweighers and feature a particularly short settling time, so that the weight of the goods being recorded can be determined as quickly as possible.

The load cells are also suitable for use in sectors such as industry, commerce, medicine and research.

The model F4883 single point load cells also feature high accuracy and react quickly. They are also insensitive to lateral and corner loading.

The load cells are easy to handle due to their simple force introduction. This is made perpendicular to the geometry.

Specifications per VDI/VDE/DKD 2638

Parameter Value
Rated load (Fnom) 8 / 15 / 20 / 50 / 100 / 200 / 300 kg
Rated load (Fnom) 18 / 33 / 44 / 110 / 220 / 441 / 661 lbs
Relative linearity error (dlin) ±0.02 % Fnom
Relative creep, 30 min ±0.02 % Fnom
Relative reversibility error (v) ±0.02 % Fnom
Relative deviation of zero signal (dS₀) ±5 % Fnom
Temperature effect on zero signal (TK₀) ≤ ±0.014 % / 10 K
Temperature effect on characteristic value (TKC) ≤ ±0.02 % / 10 K
Force limit (FL) 150 % Fnom
Breaking force (FB) 200 % Fnom
Material of measuring body Aluminium
Rated temperature range (BT, nom) -10 … +40 °C [14 … 104 °F]
Operating temperature range (BT, G) -20 … +65 °C [-4 … 149 °F]
Input resistance (Re) 410 ±10 Ω
Output resistance (Ra) 350 ±5 Ω
Insulation resistance (Ris) ≥ 5,000 MΩ / DC 100 V
Output signal (Cnom) 2.0 ±0.2 mV/V
Electrical connection Measuring cable ∅ 5 × 3,000 mm [∅ 0.2 × 118 in]
Supply voltage (UB, nom) DC 5 … 10 V (max. 15 V)
Ingress protection IP66
Platform size 600 × 500 mm [23.62 × 19.69 in]
Weight 0.6 kg [1.32 lbs]

1) Relative linearity error is specified in accordance with guideline VDI/VDE/DKD 2638 chap. 3.2.6.