DINI ARGEO / RCD Series, Dini Argeo Digital Column Load Cells, Stainless Steel

  • METROLOGICAL:

    • Rated capacity (Cn): 30/40t
    • Combined error: ± 0,014 %Cn
    • Temperature effect on zero: 0,0016 %Cn/°C
    • Temperature effect on sensitivity: 0,0012 %Cn/°C
    • Creep error (30 min.): 0,021 %Cn

    LEGAL METROLOGY OIML R60

    • Accuracy class: C4
    • Max. number of intervals (nmax): 4000e OIML
    • Minimum verification interval (vmin): 10000
    • Z= Emax/(2xDR): 4000

    ELECTRICAL

    • Nominal range of excitation voltage: 10 – 16Vdc
    • Rated output: 200000d
    • Current consumption: 35mA
    • Conversion type: Delta-sigma
    • Internal resolution: 24 bit
    • Converter rate: max. 100 conv./sec.
    • RS485 interface communication rate: 4800/19200 bit/sec.
    • Protection against electrostatic discharge according to IEC 61326-1

    GENERAL

    • Service temperature range: -20 ~ +60 °C
    • Compensated temperature range: -10 ~ +40 °C
    • Safe load limit: 150% Emax
    • Ultimate overload: 300% Emax
    • Protection degree IP68
    • Load cells with stainless steel body
    • 6-core armoured cable, PVC sheath, 18m length, 9mm diameter.
    • Nickel plated steel cable gland.
    • Armoured Anti Rodent Cable with Stainless Steel Armour.
    • Self-centring spherical bases.
    • Equipped with anti-rotation system, to be combined with KRCA cups for proper operation
Tag:
브랜드:

설명

RCD Series, Dini Argeo Digital Column Load Cells, Stainless Steel

RCD Series, Dini Argeo Digital Column Load Cells

상품평

아직 상품평이 없습니다.

“DINI ARGEO / RCD Series, Dini Argeo Digital Column Load Cells, Stainless Steel”의 첫 상품평을 남겨주세요