설명
Double Shear Beam loadcell HM460
- CE-verification prepared
- double shear beam load cell
- measuring element made of stainless steel
- hermetically sealed, fully welded
- protection class IP68 (EN 60529)
- easy installation
- application: tanks and silos weighing systems with very linear and low profile requirements
- optionally available in explosion-proof version

- capacities: 5 t, 10 t, 20 t, 50 t
Extra information
| Model | Nominal capacity | Accuracy OIML | Min. divisions |
| HM460 5t | 5 t | 3000d | 0.5 kg |
| HM460 10t | 10 t | 3000d | 1 kg |
| HM460 20t | 20 t | 3000d | 2 kg |
| HM460 30t | 30 t | 3000d | 3 kg |
| HM460 50t | 50 t | 3000d | 5 kg |
| HM460 75t | 75 t | 3000d | 7.5 kg |
| HM460 100t | 100 t | 3000d | 10 kg |
| Specifications | Data | Unit |
| Nominal capacities (Ln) | 5 – 100 | t |
| Accuracy class | 3000 | n.OIML |
| Minimum dead load | 0 | % Ln |
| Service load | 150 | % Ln |
| Safe load limit | 200 | % Ln |
| Total error | < ± 0,017 | % Sn |
| Repeatability error | < ±0,015 | % Sn |
| Temperature effect: On zero On sesitivity |
±0,01 ±0,006 |
% Sn/5K % Sn/5K |
| Creep error (30 minutes ) | < ± 0,016 | % Sn |
| Temperature compensation | -10…+40 | °C |
| Temparature limits | -30…+70 | °C |
| Nominal sensitivy (Sn) | 2 ± 0,1% | mV/V |
| Nominal input voltage | 10 | V |
| Maximum input voltage | 15 | V |
| Imput impedance | 800 ± 30 | Ω |
| Output impedance | 700 ± 3 | Ω |
| No load output | < ± 2 | % Sn |
| Insulation resistance | > 5000 | MΩ |
| Maximum deflection (at Ln) | 0,6 – 1 | mm |



상품평